Labware | code readers | cappers & decappers | sample management | starter packs | services
Tube Configurator

Sample management equipment

Sample Management Software

Tube Sorter

For cherry picking or re-arraying your sample storage library, the Tubesorter can quickly transfer tubes between multiple 96 tube racks while maintaining sample identity. The advanced tube management system supports sorting of a nearly unlimited number of tubes. The robotics allows for the unattended processing of 9 or 20 tube racks at a time. For projects over 1,920 tubes, the tube racks can be exchanged dynamically.



System requirements
Dimensions

Weight
Voltage
: Windows 7 / Vista / XP
: 43 x 45.5 x 40.5 cm /
17 x 18 x 16 inch
: 24 kg / 52.9 lbs (XL9)
: 110-220 VAC 60Hz

Superior features
  • Work list based processing for fast and reliable operations
  • Capacity of 9 or 20 tube racks - sorts 300 to 900 tube per hour
  • Intuitive software
  • Sample tracking, work list based software, integrated 2D tube scanner (Data-Matrix)
  • Individual tube identification
  • Barcoded rack set-up
  • Detailed LOG files
  • Additional options: ActiveX toolkit, integrated 2D code reader, analytical balance for weighing tubes, tube level check
Download more information on the TubeSorters here:
Art. nr. Description Unit
SAMPLE MANAGEMENT SYSTEM
XL20 Tube Sorter Systems 20 rack capacity
LXL20Base Model - sort only (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LXL20CXL20 Tube Sorter System with 2D code reader (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LXL20SXL20 Tube Sorter System with Analytical Balance (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LXL20CSXL20 Tube Sorter Sytem with 2D code reader and Balance (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LCRXL20Base Model - COLD ROOM sort only (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LXL20LCXL20 LevelCheck Add-on1 unit
LCRXL20CXL20 Tube Sorter System - COLD ROOM with 2D code reader (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LCRXL20SXL20 Tube Sorter System - COLD ROOM with Analytical Balance (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LCRXL20CSXL20 Tube Sorter Sytem - COLD ROOM with 2D code reader and Balance (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LXLSUPScale Upgrade Kit Tubesorter1 unit
LMIC20_0.75Rack Supports for XL20 for 0,75ml tubes1 unit
LMIC20_0.75SCRack Supports for XL20 for 0,75ml Screw top tubes1 unit
LMIC20_0.5Rack Supports for XL20 for 0,5ml tubes1 unit
LINS1One day onsite installation and training - this is required for all tube sorter systems1 unit
LXLATXActive X Tool Kit1 unit
LX20DellDell P4 computer (no Monitor), key board, mouse, Windows XP, pre-loaded XL20 software1 unit
XL9 Tube Sorter Systems 9 rack capacity
LXL9Base Model - sort only (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LXL9CXL9 Tube Sorter System with 2D code reader (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LXL9SXL9 Tube Sorter System with Analytical Balance (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LXL9CSXL9 Tube Sorter System with 2D code reader and analytical Balance (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LXL9LCXL9 LevelCheck Add-on1 unit
LCRXL9Base Model - sort only (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LCRXL9CXL9 Tube Sorter System - COLD ROOM with 2D code reader (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LCRXL9SXL9 Tube Sorter System - COLD ROOM with Analytical Balance (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LCRXL9CSXL9 Tube Sorter System - COLD ROOM with 2D code reader and analytical Balance (for Micronic 1.40ml, Matrix 1.20ml and Abgene 1.20ml) (Rack adapters required for 0.50ml, 0.75ml and 1.10ml tubes)1 unit
LXLSUPScale Upgrade Kit Tubesorter1 unit
LMIC9_0.75Rack Supports for XL9 for 0,75ml tubes1 unit
LMIC9_0.75SCRack Supports for XL9 for 0,75ml Screw top tubes1 unit
LMIC9_0.5Rack Supports for XL9 for 0,50ml tubes1 unit
LINS1One day onsite installation and training - this is required for all tube sorter systems1 unit
LXLATXActive X Tool Kit1 unit
LX9DellDell P4 computer (no Monitor), key board, mouse, Windows XP, pre-loaded XL9 software1 unit

Request a quote

Other visitors also viewed



Get in touch with a Specialist

Micronic America:
+1 484 480 3372
Micronic Europe:
+31 (0)320 277070
E-mail:
sales@micronic.com
Download catalog

sign up to our newsletter!